Mission-Critical Vertical Logistics for Hyperscale & AI Infrastructure.
Data center elevators

In a hyperscale data center, vertical transportation is not simply a building service. It is part of the operational infrastructure supporting the movement of server racks, AI/GPU equipment, UPS systems, battery cabinets, electrical infrastructure and cooling equipment.
EGL Elevators develops mission-critical elevator systems engineered specifically for data center logistics, combining heavy-duty mechanical design, controlled motion, precision handling, digital integration and project-specific engineering.
MOVE CRITICAL EQUIPMENT SAFELY. PRECISELY. RELIABLY — 24/7.
EGL Data Center Elevators are developed around the actual logistics requirements of the facility, rather than around a conventional elevator configuration.
Engineering parameters
From concept design through engineering, manufacturing, installation, commissioning and lifecycle service.
5,000 KG. BUILT FOR HIGH-DENSITY DATA CENTERS.
A dedicated elevator configuration for demanding data center applications.
Higher-capacity configurations can be engineered according to travel, building geometry, duty cycle and equipment logistics.
DESIGNED AROUND THE LOAD
The elevator cabin is engineered around the dimensions and handling requirements of the equipment being transported.
Typical applications
Cabin geometry, door dimensions and floor configuration can accommodate pallet trucks, electric pallet jacks and dedicated electric rack movers
For data centers, clear opening, cabin height, floor interface and point-load resistance are engineering parameters — not secondary accessories.
CONTROLLED MOVEMENT FOR CRITICAL EQUIPMENT
High capacity alone is not sufficient.
EGL engineering focuses on controlled acceleration, deceleration and stopping to minimise mechanical stress during the transportation of sensitive IT infrastructure.
The objective is controlled vertical transportation of critical equipment throughout the complete travel.
Data center equipment frequently generates concentrated loads rather than uniformly distributed loads.
EGL can engineer the elevator floor considering:
Rack wheel loads · Pallet wheel loads · Rack-mover loads · Dynamic loads · Impact loads · Threshold loads
Floor construction, protection and surface finish are configured according to the specific operational requirements of the project.
Designed for intensive logistics operations.
Door performance is treated as a reliability and availability parameter.
24/7 OPERATION
The elevator architecture can incorporate:
The elevator electrical architecture can be coordinated with the data center power strategy.
Typical architecture
NORMAL POWER → EMERGENCY / GENERATOR POWER → UPS-SUPPORTED CONTROL & RESCUE FUNCTIONS
Depending on the project:
Controlled recovery · Designated landing · Emergency lighting · Emergency communication · Door operation · Controlled return · Building emergency-system integration.
Project-specific configurations can include:
Fire recall · Firefighter operation · Protected electrical supply · Emergency communication · Fire-rated landing interfaces · Dedicated emergency controls
Where applicable, firefighter operation is developed according to EN 81-72. Fire behaviour and recall are addressed through the applicable requirements, including EN 81-73, while fire-resistance classification of landing doors is addressed by EN 81-58.
These standards are complementary to the base elevator safety requirements and are applied according to the specific elevator configuration and building fire strategy.
For seismic applications, EGL can develop dedicated configurations incorporating:
For European projects, EN 81-77 addresses additional requirements for elevators installed in buildings designed for seismic conditions.
For the wider data-center infrastructure, ISO/IEC TS 22237-30:2022 addresses earthquake risk and impact analysis for data centers.
BMS / DCIM
The elevator can become an integrated component of the data center’s digital infrastructure.
Integration
BMS
Building Management System
DCIM
Data Center Infrastructure Management
SECURITY SYSTEMS
Access & physical security
REMOTE MONITORING
Operational & maintenance data
Available data
Position · Direction · Operating mode · Door status · Load · Availability · Fault status · Emergency status · Cycle count · Maintenance parameters
Project-specific integration can include BACnet, Modbus and secure API-based interfaces.
FROM PREVENTIVE TO CONDITION-BASED SERVICE
EGL can integrate condition-monitoring functions covering:
Motor parameters · Inverter · Door cycles · Brake condition · Temperature · Vibration · Levelling accuracy · Fault history · Operating cycles
The objective is to identify performance deterioration before it becomes an operational failure.
When connected to the data center’s infrastructure, the elevator becomes part of the wider OT — Operational Technology environment.
EGL can develop:
Secure communication gateways
Authenticated remote access
Role-based access
Event logging
Controlled firmware updates
Network segregation
Cybersecurity requirements are defined according to the client’s IT/OT security architecture.
For projects requiring an industrial cybersecurity framework, the architecture can be coordinated with applicable IEC 62443 principles.
FROM CONCEPT TO COMMISSIONING
CONCEPT DESIGN
↓
3D ENGINEERING
↓
BIM COORDINATION
↓
STRUCTURAL VERIFICATION
↓
MANUFACTURING
↓
INSTALLATION
↓
COMMISSIONING
ISO/TS 8100-10:2025 defines information requirements for integrating lift information into BIM workflows during pre-design, schematic and detailed design phases.
ENGINEERED ACCORDING TO THE APPLICABLE REQUIREMENTS
EUROPEAN ELEVATOR FRAMEWORK
Directive 2014/33/EU
Lifts and safety components
EN 81-20
Safety rules for passenger and goods-passenger elevators
EN 81-50
Design rules, calculations, examinations and tests of elevator components
ISO 8100-1:2026
Safety rules for passenger and goods-passenger elevators
ISO 8100-2:2026
Design rules, calculations, verification and testing of elevator components
ISO 8100-1:2026 is the current international edition for passenger and goods-passenger lifts and covers traction, positive-drive and hydraulic elevators within its defined scope. (ISO)
GOODS-ONLY APPLICATIONS
EN 81-31
Applicable to accessible goods-only elevators within its defined scope.
This distinction is important: a goods-only elevator and a goods-passenger elevator are not automatically governed by the same normative framework.
SPECIAL APPLICATIONS
EN 81-72 — Firefighters elevators
EN 81-73 — Behaviour in case of fire
EN 81-58 — Fire-resistance testing of landing doors
EN 81-77 — Seismic conditions
EN 81-28 — Remote alarm
EN 13015 — Maintenance
BIM
ISO/TS 8100-10:2025 — BIM information requirements for lifts.
EGL engineering can also be coordinated with the standards governing the wider data-center environment.
ISO/IEC 22237
The ISO/IEC 22237 family establishes a framework for data-center facilities and infrastructure, addressing aspects including availability, security and energy-efficiency enablement. (ISO)
ISO/IEC 22237-6:2024 specifically addresses physical security systems and protection against unauthorised access, intrusion and certain internal/external environmental events. (ISO)
ISO/IEC TS 22237-31:2026 defines KPIs for data-center resilience, dependability, fault tolerance and availability tolerance, including maintainability and recoverability. (ISO)
These standards provide the data-center infrastructure context; they do not replace the specific conformity requirements applicable to the elevator itself.
EGL DATA CENTER SERVICE
For critical installations, EGL can define a project-specific:
MISSION-CRITICAL SERVICE AGREEMENT
Including, according to the contractual scope:
Availability targets and response times are defined contractually for each installation.
01 — CONCEPT
Logistics requirements & preliminary elevator architecture
02 — ENGINEERING
Mechanical, electrical, structural & control-system development
03 — BIM COORDINATION
Architectural, structural & MEP integration
04 — MANUFACTURING
Controlled production & factory testing
05 — INSTALLATION
Site integration & commissioning
06 — OPERATION
Monitoring, maintenance, diagnostics & lifecycle support.
A VERTICAL TRANSPORTATION SYSTEM ENGINEERED AS PART OF THE CRITICAL INFRASTRUCTURE.
HEAVY DUTY
PRECISION MOTION
24/7 AVAILABILITY
DIGITAL INTEGRATION
MISSION-CRITICAL SERVICE
EGL develops Data Center Elevator solutions for the operational requirements of each facility — from Enterprise and Edge Data Centers to Hyperscale and AI/HPC infrastructure.
From the first technical concept to long-term operation, EGL works with developers, engineering consultants, EPC contractors, general contractors and data center operators to define the appropriate vertical transportation architecture for each project.
ENGINEERED FOR UPTIME.
DESIGNED FOR PRECISION.
BUILT FOR THE DATA CENTER.
TECHNICAL CONSULTATION → info@eglelevators.com
Per ricevere schede tecniche, supporto progettuale o sviluppare una soluzione personalizzata per il tuo progetto architettonico:
EGL Elevators Italia
info@eglelevators.com
www.eglelevators.com