Data center elevators

Mission-Critical Vertical Logistics for Hyperscale & AI Infrastructure.

Ascensori per data center
Vertical transportation engineered for the most demanding data center environments

In a hyperscale data center, vertical transportation is not simply a building service. It is part of the operational infrastructure supporting the movement of server racks, AI/GPU equipment, UPS systems, battery cabinets, electrical infrastructure and cooling equipment.

EGL Elevators develops mission-critical elevator systems engineered specifically for data center logistics, combining heavy-duty mechanical design, controlled motion, precision handling, digital integration and project-specific engineering.

MOVE CRITICAL EQUIPMENT SAFELY. PRECISELY. RELIABLY — 24/7.

Engineered around the data center

EGL Data Center Elevators are developed around the actual logistics requirements of the facility, rather than around a conventional elevator configuration.
Engineering parameters

  • Rack dimensions & weight
  • Pallet & rack-mover geometry
  • Wheel & point loads
  • Loading sequences
  • Floor-to-floor logistics
  • Equipment protection
  • Power architecture
  • Emergency operation
  • Fire strategy
  • Seismic requirements
  • BMS / DCIM integration
  • Maintenance & serviceability

From concept design through engineering, manufacturing, installation, commissioning and lifecycle service.

EGL DC-5000

5,000 KG. BUILT FOR HIGH-DENSITY DATA CENTERS.
A dedicated elevator configuration for demanding data center applications.

  • 5,000 kg (up to 20.000 kg) rated load
  • Up to 1.0 m/s
  • Gearless traction
  • 24/7 heavy-duty operation
  • Large-format cabin
  • Large clear door openings
  • Single or dual entrance
  • Through-car configuration
  • Precision levelling
  • Heavy-duty floor & cabin protection

Higher-capacity configurations can be engineered according to travel, building geometry, duty cycle and equipment logistics.

Ascensori per data center
Rack & Pallet Logistics

DESIGNED AROUND THE LOAD
The elevator cabin is engineered around the dimensions and handling requirements of the equipment being transported.
Typical applications

  • SERVER RACKS
  • AI / GPU RACKS
  • UPS
  • BATTERY SYSTEMS
  • PDU & SWITCHGEAR
  • COOLING EQUIPMENT
  • HVAC COMPONENTS
  • TECHNICAL EQUIPMENT
  • PALLETIZED LOADS

Cabin geometry, door dimensions and floor configuration can accommodate pallet trucks, electric pallet jacks and dedicated electric rack movers


For data centers, clear opening, cabin height, floor interface and point-load resistance are engineering parameters — not secondary accessories.

Precision Motion

CONTROLLED MOVEMENT FOR CRITICAL EQUIPMENT
High capacity alone is not sufficient.
EGL engineering focuses on controlled acceleration, deceleration and stopping to minimise mechanical stress during the transportation of sensitive IT infrastructure.

  • Controlled acceleration & deceleration
  • Low jerk
  • Precision levelling
  • Reduced vibration
  • Smooth door operation
  • Controlled load movement

The objective is controlled vertical transportation of critical equipment throughout the complete travel.

Heavy-Duty Floor Engineering

Data center equipment frequently generates concentrated loads rather than uniformly distributed loads.

EGL can engineer the elevator floor considering:

Rack wheel loads · Pallet wheel loads · Rack-mover loads · Dynamic loads · Impact loads · Threshold loads

Floor construction, protection and surface finish are configured according to the specific operational requirements of the project.

High-Cycle Door Systems

Designed for intensive logistics operations.

  • Large clear openings
  • Heavy-duty door operators
  • Reinforced panels & thresholds
  • Full-height light curtains
  • Obstruction detection
  • Door-cycle monitoring
  • Impact protection
  • Replaceable wear components

Door performance is treated as a reliability and availability parameter.

Mission-Critical Architecture

24/7 OPERATION
The elevator architecture can incorporate:

  • Industrial-grade controls
  • Gearless drives
  • VVVF technology
  • Monitored safety circuits
  • Emergency power interfaces
  • Remote diagnostics
  • Condition monitoring
  • Predictive maintenance
  • Critical spare-parts strategy
Power & Emergency Operation

The elevator electrical architecture can be coordinated with the data center power strategy.

Typical architecture

NORMAL POWER → EMERGENCY / GENERATOR POWER → UPS-SUPPORTED CONTROL & RESCUE FUNCTIONS

Depending on the project:

Controlled recovery · Designated landing · Emergency lighting · Emergency communication · Door operation · Controlled return · Building emergency-system integration.

Fire & Firefighter Operation

Project-specific configurations can include:

Fire recall · Firefighter operation · Protected electrical supply · Emergency communication · Fire-rated landing interfaces · Dedicated emergency controls

Where applicable, firefighter operation is developed according to EN 81-72. Fire behaviour and recall are addressed through the applicable requirements, including EN 81-73, while fire-resistance classification of landing doors is addressed by EN 81-58.

These standards are complementary to the base elevator safety requirements and are applied according to the specific elevator configuration and building fire strategy.

Seismic Engineering

For seismic applications, EGL can develop dedicated configurations incorporating:

  • Reinforced guide systems
  • Seismic anchoring
  • Counterweight retention
  • Seismic interfaces
  • Post-event inspection logic
  • Project-specific structural calculations

For European projects, EN 81-77 addresses additional requirements for elevators installed in buildings designed for seismic conditions.

For the wider data-center infrastructure, ISO/IEC TS 22237-30:2022 addresses earthquake risk and impact analysis for data centers.

Digital Integration

BMS / DCIM

The elevator can become an integrated component of the data center’s digital infrastructure.

Integration

BMS
Building Management System

DCIM
Data Center Infrastructure Management

SECURITY SYSTEMS
Access & physical security

REMOTE MONITORING
Operational & maintenance data

Available data

Position · Direction · Operating mode · Door status · Load · Availability · Fault status · Emergency status · Cycle count · Maintenance parameters

Project-specific integration can include BACnet, Modbus and secure API-based interfaces.

Predictive Maintenance

FROM PREVENTIVE TO CONDITION-BASED SERVICE

EGL can integrate condition-monitoring functions covering:

Motor parameters · Inverter · Door cycles · Brake condition · Temperature · Vibration · Levelling accuracy · Fault history · Operating cycles

The objective is to identify performance deterioration before it becomes an operational failure.

Cybersecurity By Design

When connected to the data center’s infrastructure, the elevator becomes part of the wider OT — Operational Technology environment.

EGL can develop:

Secure communication gateways
Authenticated remote access
Role-based access
Event logging
Controlled firmware updates
Network segregation

Cybersecurity requirements are defined according to the client’s IT/OT security architecture.

For projects requiring an industrial cybersecurity framework, the architecture can be coordinated with applicable IEC 62443 principles.

BIM & Engineering Integration

FROM CONCEPT TO COMMISSIONING

CONCEPT DESIGN
↓
3D ENGINEERING
↓
BIM COORDINATION
↓
STRUCTURAL VERIFICATION
↓
MANUFACTURING
↓
INSTALLATION
↓
COMMISSIONING

ISO/TS 8100-10:2025 defines information requirements for integrating lift information into BIM workflows during pre-design, schematic and detailed design phases.

Regulatory Framework

ENGINEERED ACCORDING TO THE APPLICABLE REQUIREMENTS

EUROPEAN ELEVATOR FRAMEWORK
Directive 2014/33/EU
Lifts and safety components

EN 81-20
Safety rules for passenger and goods-passenger elevators

EN 81-50
Design rules, calculations, examinations and tests of elevator components

ISO 8100-1:2026
Safety rules for passenger and goods-passenger elevators

ISO 8100-2:2026
Design rules, calculations, verification and testing of elevator components

ISO 8100-1:2026 is the current international edition for passenger and goods-passenger lifts and covers traction, positive-drive and hydraulic elevators within its defined scope. (ISO)

GOODS-ONLY APPLICATIONS

EN 81-31

Applicable to accessible goods-only elevators within its defined scope.

This distinction is important: a goods-only elevator and a goods-passenger elevator are not automatically governed by the same normative framework.

SPECIAL APPLICATIONS

EN 81-72 — Firefighters elevators
EN 81-73 — Behaviour in case of fire
EN 81-58 — Fire-resistance testing of landing doors
EN 81-77 — Seismic conditions
EN 81-28 — Remote alarm
EN 13015 — Maintenance

BIM

ISO/TS 8100-10:2025 — BIM information requirements for lifts.

Data Center Infrastructure

EGL engineering can also be coordinated with the standards governing the wider data-center environment.

ISO/IEC 22237

The ISO/IEC 22237 family establishes a framework for data-center facilities and infrastructure, addressing aspects including availability, security and energy-efficiency enablement. (ISO)

ISO/IEC 22237-6:2024 specifically addresses physical security systems and protection against unauthorised access, intrusion and certain internal/external environmental events. (ISO)

ISO/IEC TS 22237-31:2026 defines KPIs for data-center resilience, dependability, fault tolerance and availability tolerance, including maintainability and recoverability. (ISO)

These standards provide the data-center infrastructure context; they do not replace the specific conformity requirements applicable to the elevator itself.

Mission-Critical Service

EGL DATA CENTER SERVICE
For critical installations, EGL can define a project-specific:
MISSION-CRITICAL SERVICE AGREEMENT
Including, according to the contractual scope:

  • 24/7 remote monitoring
  • Critical alarm management
  • Remote diagnostics
  • Defined response times
  • On-site intervention targets
  • Preventive maintenance
  • Predictive maintenance
  • Critical spare-parts availability
  • Technical escalation
  • Performance reporting

Availability targets and response times are defined contractually for each installation.

Engineered For The Data Center Lifecycle

01 — CONCEPT

Logistics requirements & preliminary elevator architecture

02 — ENGINEERING

Mechanical, electrical, structural & control-system development

03 — BIM COORDINATION

Architectural, structural & MEP integration

04 — MANUFACTURING

Controlled production & factory testing

05 — INSTALLATION

Site integration & commissioning

06 — OPERATION

Monitoring, maintenance, diagnostics & lifecycle support.

EGL Data Center Elevator

A VERTICAL TRANSPORTATION SYSTEM ENGINEERED AS PART OF THE CRITICAL INFRASTRUCTURE.

HEAVY DUTY

PRECISION MOTION

24/7 AVAILABILITY

DIGITAL INTEGRATION

MISSION-CRITICAL SERVICE

EGL develops Data Center Elevator solutions for the operational requirements of each facility — from Enterprise and Edge Data Centers to Hyperscale and AI/HPC infrastructure.

From the first technical concept to long-term operation, EGL works with developers, engineering consultants, EPC contractors, general contractors and data center operators to define the appropriate vertical transportation architecture for each project.

ENGINEERED FOR UPTIME.

DESIGNED FOR PRECISION.

BUILT FOR THE DATA CENTER.